VOLUMETRIC ROTARY PISTON WATER METER
LXH-15A~20AVOLUMETRIC ROTARY PISTON WATER METER...
一、Feature:
1.Adopt volumetric rotary piston principle of measurement with conformity to ISO 4064 class D
2.Hith sensitivity enables the accurate measurement even at a low flow rate of 5 l/h
3.No location limitation for installation.Accuracy is not to be affected wherever installed at a horizontal,vertical or inclined pipeline
4.Register is sealed with a special liquid to keep a clear reading in long term service
5.Mechanical parts use of high-quality material to ensure a stable characteristic
6.Plastic coating for surface treatment with a nice look and for a long life-span

二、Description:
This range of water meter is used to measure the total quantity of cold potable water which consumed in household or a resident unit,passing through the pipelione.

三、Working condition:
Water temperature:≤40℃
Working pressure:≤1MPa

四、Main technical data:

Meter Size
(mm)

Class
class

overload Flow

Nominal Flow

Transitional Flow

Min Flow

Starting flow

Min Reading lectura

Max. Reading lectura

m3/h

m3

15

C

3

1.5

22.5

15.0

6.0

0.0001

9999

D

17.25

11.25

5.0

20 C 5 2.5 37.5 25 7 0.0001 9999
D 28.75 18.75 7

五、Dimensions and weight:

Meter Size
mm

Length L

Width B

Height H

Connecting Thread

Weight
KG

mm

Connecting Thread D

15

200

115

90

R 1/2

1.1

20

270

165

90

R 3/4

1.8



DRINKING WATER MEASURING INSTRUMENT
LYH-8 ,LYH-8SDRINKING WATER MEASURING INSTRUMENT...
一、Feature:
1. Adopt volumetric rotary piston principle of measurement.
2. High semsitivity enables the measurement even at a low flow vate of 2L/h
3. Vacuum Sealed register to keep a clear ptewentation in long rate service.
4. Mechanical parts use of high quality material to ensure a long life span.
5. Main casing use of stainless steel with a nice look and high sturdiness.
(The main casing of LYH-8S is use of plastic)

二、Application:
Measuring the volume of drinking water passing through the pipeline.

三、Working Condition:
Water temperature≤40℃
Water pressure ≤0.6MPa

四、Main technical data:

Meter Size
(mm)

Class
class

overload Flow

Nominal Flow

Transitional Flow

Min Flow

Starting flow

Min Reading lectura

Max. Reading lectura

m3/h

m3

8

C

3

1.5

22.5

15.0

6.0

0.0001

9999


五、Dimensions and weight:

Tyep

Size

Length

Width

Height

Connecting Thread

Weight

mm

D

kg

LYH-8

8

110

82

91

G3/4B

0.89

LYH-8S

8

100

82

91

G3/4B

0.39



Voltman Magnetic-drive Dry-dial Water Meter
LXLGY-50~250Voltman Magnetic-drive Dry-dial Water Meter...
一、Feature:
Measuring the volume of cold potable water passing through the pipeline.
Removable element for facilitating installation and maintenance,copper sealed register,long term clear reading,inter-exchangeable parts,magnetic transmission,low driving resistance.Reliable sensitive action,small pressure loss,long working life,etc.also can add the "Pulse Remote Transmission "device , long distance reading.

二、Working condition:
Cold water temperature:≤40℃ , Hot water temperature: ≤90℃
Working pressure:≤1MPa

三、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Initiating the flow

Min Reading lectura

Max Reading lectura

m3/h

1/h

m3

50

B

30

15

3

0.45

150

0.01

9999999

65

B

50

25

5

0.75

170

0.01

9999999

80

B

80

40

8

1.2

280

0.01

9999999

100

B

120

60

12

1.8

400

0.01

9999999

125

B

200

100

20

3

800

0.01

9999999

150

B

300

150

30

4.5

1200

0.01

9999999

200

B

500

250

50

7.5

2250

0.01

9999999

250

B

800

400

80

12

2500

0.01

9999999


四、Dimensions and weight:

Meter Size
mm

Length L

Width B

Height H

Connecting Flange

Weight
KG

mm

D

Bolt Circle diaD1

Connecting Bolt dia

50

200

175

250

165

125

4×M16

12

65

200

185

255

185

145

4×M16

13

80

225

200

265

200

160

8×M16

15

100

250

220

275

220

180

8×M16

19

125

250

245

285

245

210

8×M16

22

150

300

285

375

285

240

8×M20

47

200

350

345

400

340

295

8×M20

48

250

450

395

484

395

350

12×M20

110



IMPULSE TRANSFER WATER METER
LXSGY-15~50IMPULSE TRANSFER WATER METER...
一、Feature:
1.Transmission sensors for option:reed switch/hall effect/optical switch
2.Sensors with high stability and resistance to interference enable a long life span
3.Keep its all measuring data
4.Sustain its measuring accuracy and numeral display
5.Unique design and advanced testing measures ensure a secure transmission
6.Maximum distance between connected meter and a data collector:150m
7.Applicable to various kinds of data collector

二、Main technical data(notes):
1.pulse constant:30 pulses/m3 unless otherwise stated
2.connecting wire 1m-1.5m
3.connecting wire can choose of stainless steel jacket wire at 500m-900m long with end connecting threaded M8 X 1 at 5m long
4.sensors connecting means:
a.two cores wire for reed switch sensor with no polarity
b.three cores wire for hall effect sensor,red for voltage positive polar,green for output,black for common ground
c.four cores wire for optical switch sensor,red for voltage positive polar,green for output,yellow for standby detection, black for common ground。

三、Description:
This range of water meter is used to measure the water which consumed in household or a resident unit,passing through the pipeline.As equipped with a built in sensor,it can be used for a remote reading transmission system.

四、Working condition:
Water temperature:≤50℃(cold) , :≤90℃(hot)
Working pressure:≤1MPa

五、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Min Reading lectura

Max Reading lectura

m3/h

l/h

m3

15

B

3

1.5

120

30

0.0001

99999

20

B

5

2.5

200

50

0.0001

99999

25

B

7

3.5

280

70

0.0001

99999

32

B

12

6.0

480

120

0.0001

99999

40

B

20

10

800

200

0.0001

99999

50

B

30

15

3000

450

0.0001

99999

HORIZONTAL WOLTMAN WATER METER
LXLC-80~150HORIZONTAL WOLTMAN WATER METER...
一、Feature:
1.Dry-dial,Magnetic drive
2.Vacuum sealed register ensures the dial kept free from fog and keep the reading clear in a long term service
3.Selected high quality materials for steady & reliable characteristic
4.Measuring accuracy conform to ISO 4064 class B Standard
5.Low head loss
6.Register for universal use within this range detachable without removing the meter from the pipeline for a easy maintenance and replacement

二、Description:
This range of water meter is used to measure the total quantity of cold water which consumed in industrial enterprise & mining,passing through the pipeline.

三、Working condition:
Cold water temperature:≤40℃ , Hot water temperature: ≤90℃
Working pressure:≤1MPa

四、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow
(qs)m3/h

Nominal Flow
(qp)m3/h

Transitional Flow
(qt) (L/h)

Min Flow
(qmin)(L/h)

80

B

80

40

8

1.2

100

B

120

60

12

1.8

150

B

200

100

20

3.0


五、Dimensions and weight:

Meter Size
(mm)

Length L
(mm)

Height H
(mm)

Connecting Flange

Weight
(kg)

D(mm)

Bolt Circle diaD1 D1(mm)

Connecting Bolt dia (Pcs.)

80

370

310

200

160

8×M16

27

100

370

315

220

180

8×M16

29

150

500

445

285

240

8×M20

80


HORIZONTAL WOLTMAN DETACHABLE MAGNET-DRIVE DRY-DIAL WATER METER
LXLG-50~250HORIZONTAL WOLTMAN DETACHABLE MAGNET-DRIVE D...
一、Feature:
1.Dry-dial,Magnetic drive
2.Vacuum sealed register ensures the dial kept free from fog and keep the reading clear in a long term service
3.Selected high quality materials for steady & reliable characteristic
4.Measuring accuracy conform to ISO 4064 class B Standard
5.Low head loss
6.Register for universal use within this range detachable without removing the meter from the pipeline for a easy maintenance and replacement

二、Description:
This range of water meter is used to measure the total quantity of cold water which consumed in industrial enterprise & mining,passing through the pipeline.

三、Working condition:
Cold water temperature:≤40℃ , Hot water temperature:≤90℃
Working pressure:≤1MPa

四、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Initiating the flow

Min Reading

Max Reading

m3/h

1/h

m3

50

B

30

15

3

0.45

150

0.01

9999999

65

B

50

25

5

0.75

170

0.01

9999999

80

B

80

40

8

1.2

280

0.01

9999999

100

B

120

60

12

1.8

400

0.01

9999999

125

B

200

100

20

3

800

0.01

9999999

150

B

300

150

30

4.5

1200

0.01

9999999

200

B

500

250

50

7.5

2250

0.01

9999999

250

B

800

400

80

12

2500

0.01

9999999


五、Dimensions and weight:

Meter Size
mm

Length L

Width B

Height H

Connecting Flange

Weight
KG

mm

OD D

Bolt Circle dia D1

Connecting Bolt dia

50

200

175

250

165

125

4×M16

12

65

200

185

255

185

145

4×M16

13

80

225

200

265

200

160

8×M16

15

100

250

220

275

220

180

8×M16

19

125

250

245

285

245

210

8×M16

22

150

300

285

375

285

240

8×M20

47

200

350

345

400

340

295

8×M20

48

250

450

395

484

395

350

12×M20

110

 

ROTARY VANE WHEEL MULTI-JET DRY-DIAL  WATER METER
LXSG-15~20ROTARY VANE WHEEL MULTI-JET DRY-DIAL WATER ...
一、Feature:
1.Dry-dial,Magnetic drive,Resistance to exterior magnet interference
2.Multi-jet
3.Selected high quality materials for steady & reliable characteristic
4. Glass vacuum sealed ensures the dial kept free from fog and keep the reading clear in a long term service
5.Measuring accuracy conform to ISO 4064 class B Standard
6.Universal use.Easy for interchange & maintenance

二、Description:
This range of water meter is used to measure the total quantity of cold potable water which consumed in household or a resident unit,passing through the pipeline.

三、Working condition:
Cold water temperature: ≤40℃ , Hot water temperature: ≤90℃
Water pressure:≤1Mpa

四、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Min Reading

Max Reading

m3/h

L/h

m3

15

A

3

1.5

150

60

0.0001

9999

B

120

30

20

A

3

2.5

250

100

0.0001

9999

B

200

50


五、Dimensions and weight:

Meter Size
mm

Length L

Width B

Height H

Connecting Thread

Weight
KG

mm

15

165

80

102

G3/4B

1.1

20

190

80

104

G1B

1.4



High Sensitivity Multi-jet Cold (Hot) Water Meter
LXS-15~25High Sensitivity Multi-jet Cold (Hot) Water ...
一、Feature:
1.High sensitivity: start-up flow ≤2L/h
2.Model choice: Makes each type water meter
3.Measuring accuracy conform to ISO 4064 Class B Standard

二、Description:
This range of water meter is used to measure the total quantity of cold potable water which consumed in household or a resident unit,passing through the pipelione.

三、Working condition:
Cold water temperature:≤40℃ , Hot water temperature:≤90℃
Working pressure:≤1MPa

四、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Starting flow

Min Reading

Max Reading

m3/h

l/h

m3

15

B

3

1.5

120

30

2.0

0.0001

99999

20

B

5

2.5

200

50

2.0

0.0001

99999

25 B 7 3.5 280 70 2.0 0.0001 99999

五、Dimensions and weight:

Meter Size
(mm)

Length L

Height H

Width B

Connecting Thread
D

Weight
KG

mm

15

165

104

90

G3/4B

1.3

20

190/195

106

99

G1B

1.5

25 265/225 114 103 G 11/4B 2.3


 

 

SINGLE JET DRY TYPE VANE WHEEL
LXSG-13DSINGLE JET DRY TYPE VANE WHEEL...
一、Feature:
Dry type.small,light,magnetic drive,free rotating register,easy and long term clear reading etc.Magnet resistance

二、Description:
Measuring the volume of cold(hot) potable water passing through the pipeline

三、Working Condition:
Water temperature: ≤40℃for cold potable water meter
Water temperature: ≤90℃for hot potable water meter
pressure: ≤1Mpa

四、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Min Reading

Max Reading

m3/h

m3

13

A

3

1.5

150

60

0.0001

99999

B

120

30


五、Dimensions and weight:

Meter Size
mm

Length L

Width B

Height H

Connecting Thread

Weight
KG

mm

Connecting Thread D

13

80

77

85

G 3/4B

0.7



SINGLE JET DRY TYPE VANE WHEEL
LXSG-13D~25DSINGLE JET DRY TYPE VANE WHEEL...
一、Feature:
1.Dry-dial,Magnetic drive,Resistance to exterior magnet interference
2.Single-jet
3.Selected high quality materials for steady & reliable characteristic
4.Vacuum sealed register ensures the dial kept free from fog and keep the reading clear in a long term service
5.Measuring accuracy conform to ISO 4064 class B Standard
6.Inner or outer adjusting device for option
7.Small in size and Light in weight

二、Description:
This range of water meter is used to measure the total quantity of cold potable water which consumed in household or a resident unit,passing through the pipeline.

三、Working Condition :
Water temperature: ≤40℃for cold potable water meter
Water temperature: ≤90℃for hot potable water meter
pressure: ≤1Mpa

四、Main technical data:

Meter Size
(mm)

Class
class

Overload Flow

Nominal Flow

Transitional Flow

Min Flow

Min Reading

Max Reading

m3/h

m3

13

A

3

1.5

150

60

0.0001

99999

B

120

30

20

A

5

2.5

250

100

0.0001

99999

B

200

50

25

A

7

3.5

350

140

0.0001

99999

B 280 70

  五、Dimensions and weight:

Meter Size
mm

Length L

Width B

Height H

Connecting Thread

Weight
KG

mm

Connecting Thread D

13

110

80

80

G 3/4B

0.7

20

130

80

80

G 1 B

0.95

25

160

80

93

G11/4B

1.4